[ playerstage-Bugs-3365450 ] rmp driver has default max_yawspeed in degrees

classic Classic list List threaded Threaded
1 message Options
Reply | Threaded
Open this post in threaded view
|

[ playerstage-Bugs-3365450 ] rmp driver has default max_yawspeed in degrees

SourceForge.net

Bugs item #3365450, was opened at 2011-07-12 17:10
Message generated for change (Tracker Item Submitted) made by jashar
You can respond by visiting:
https://sourceforge.net/tracker/?func=detail&atid=433164&aid=3365450&group_id=42445

Please note that this message will contain a full copy of the comment thread,
including the initial issue submission, for this request,
not just the latest update.
Category: None
Group: None
Status: Open
Resolution: None
Priority: 5
Private: No
Submitted By: Jayen Ashar (jashar)
Assigned to: Nobody/Anonymous (nobody)
Summary: rmp driver has default max_yawspeed in degrees

Initial Comment:
line 279 of segwayrmp.cc should be:
        this->max_yawspeed = (int) (RTOD(cf->ReadAngle(section, "max_yawspeed", DTOR(40))));

that is, according to http://playerstage.sourceforge.net/doc/Player-cvs/player/classConfigFile.html#a6943cb2b881a5730aa5ce140d33cc5b2 , "ReadAngle" takes "value", the third argument, in radians, not degrees, so the 40 should be DTOR(40).


----------------------------------------------------------------------

You can respond by visiting:
https://sourceforge.net/tracker/?func=detail&atid=433164&aid=3365450&group_id=42445

------------------------------------------------------------------------------
Magic Quadrant for Content-Aware Data Loss Prevention
Research study explores the data loss prevention market. Includes in-depth
analysis on the changes within the DLP market, and the criteria used to
evaluate the strengths and weaknesses of these DLP solutions.
http://www.accelacomm.com/jaw/sfnl/114/51385063/
_______________________________________________
Playerstage-developers mailing list
[hidden email]
https://lists.sourceforge.net/lists/listinfo/playerstage-developers